Lenovo ThinkSystem SR655
Lenovo's single-socket 2U rack server (machine types 7Y00/7Z01) for one AMD EPYC 7002 "Rome" or 7003 "Milan" processor up to 64 cores and 280 W, with 16 DDR4-3200 DIMM slots (up to 2 TB), up to 32 x 2.5-inch or 20 x 3.5-inch drives, eight rear PCIe 4.0 slots plus an OCP 3.0 slot and room for double-wide GPUs. Aimed at storage-rich, NVMe, VDI and GPU inference workloads; it can also be ordered as a rack workstation for Windows 10/11.
Memory
- Slots
- 16 DIMM (8 channels, 2 DIMMs per channel)
- Types
- Lenovo TruDDR4 RDIMM 8, 16, 32, 64 GB and 3DS RDIMM 128 GB, 2933 MHz or 3200 MHz; RDIMM and 3DS RDIMM cannot be mixed; no persistent memory
- Speed
- 3200 MHz DIMMs run at 3200 MHz at 1 DPC and 2933 MHz at 2 DPC; 2933 MHz DIMMs run at 2933 MHz; with a 2666 MHz-bus processor all DIMMs run at 2666 MHz
- Max
- 2 TB (16 x 128 GB 3DS RDIMM); minimum 8 GB
- Population
- Populate in 8s or 16 for all channels; x4 and x8 DIMMs cannot share a channel; at most two DIMM capacities
- Protection
- ECC, SDDC (x4 DIMMs), patrol/demand scrubbing, DRAM address/command parity with replay, uncorrected ECC error retry, Post Package Repair; no mirroring or rank sparing
Storage
- Front 2.5"
- 8, 16 or 24 x 2.5" SAS/SATA or NVMe from 8-bay backplanes (e.g. 8 NVMe + 16 SAS/SATA); or no backplane
- Front 3.5"
- 8 or 12 x 3.5" SAS/SATA, or 8 x SAS/SATA + 4 x AnyBay (bays 8-11; no PCIe 4.0 NVMe drives)
- Mid
- 4 x 3.5" SAS/SATA, or 8 x 2.5" SAS/SATA or NVMe (NVMe via PCIe switch); max 155 W CPU, no GPUs or full-length cards
- Rear
- 4 x 3.5" SAS/SATA, 4 x 2.5" SAS/SATA or 4 x 2.5" NVMe (NVMe via PCIe switch)
- Maximum
- 32 x 2.5" (36 physical bays; 2.5" mid and rear are mutually exclusive) or 20 x 3.5"; 28 NVMe direct-attached or 32 NVMe at 2:1 oversubscription
- Controllers
- Onboard SATA (up to 16 drives, no RAID), onboard NVMe (up to 16 drives), RAID 530-8i, 540-8i, 730-8i, 930-8i/16i/24i, 940-8i/16i/32i (no Tri-Mode), HBA 430-8i/16i, 440-8i/16i; 4-port NVMe retimer and 810-4P/1610-4P/1611-8P NVMe switch adapters for 20+ NVMe drives
- Internal slot
- Slot 9: internal PCIe 4.0 x8 riser for a RAID adapter or HBA
- M.2 boot
- M.2 module for 1 or 2 drives: SATA RAID kit (Marvell 88SE9230, RAID 0/1) or SATA/NVMe kit (JBOD); 2242/2260/2280; needs performance fans
- Optical
- None internal; external USB DVD-RW option
Graphics
- Onboard
- ASPEED AST2500 BMC graphics, max 1920x1200 at 60 Hz
- Double-wide
- NVIDIA A100 40/80GB, A40 48GB, A30 24GB, Tesla V100/V100S, RTX A6000, RTX A4500, RTX A2000 (Windows 10/11 orders only), AMD Instinct MI210 (EPYC 7003 only); up to 2 per the GPU table (slots 1 and 7), though the guide's thermal table also lists 3-GPU configurations
- Single-wide
- NVIDIA A2 16GB, T4 16GB, Quadro P620 2GB, up to 6 (slots 1, 2, 4, 5, 7, 8); 8 x T4 by special bid
- Rules
- All GPUs identical; double-wide GPUs block the adjacent slot; with double-wide or T4 GPUs max 8 x 3.5" or 16 x 2.5" front bays, no mid/rear drives, no flash adapters; 1600 W (sometimes 1100 W) PSUs; high-performance (controlled) GPUs only on the "for AI" base models
Expansion
- Riser 1
- Slots 1-3, full height (full length, or half length with mid drives): x16/x8/x8, x16/x16, x16 in slot 1 only, or slot 3 only (with 3.5" rear bays)
- Riser 2
- Slots 4-6: x16/x8/x8 (slot 6 low profile), x16/x16, or slot 6 only (with 3.5" rear bays)
- Riser 3
- Slots 7-8, full height: x8/x8 or x16/x16 (not with rear drive bays)
- Slot 9
- Internal PCIe 4.0 x8 low profile (physically x16) for a storage controller
- OCP
- Dedicated OCP 3.0 SFF slot, PCIe 4.0 x16
- Slot layouts
- 8 rear slots; 6 slots + 4 x 2.5" rear drives; 2 slots + 4 x 3.5" rear drives
Networking
- OCP 3.0
- Optional 2- or 4-port adapters: 1 GbE (Broadcom 5719, Intel I350), 10GBASE-T (Broadcom 57416/57454, Intel X710-T2L/T4L, Marvell QL41132), 10/25 GbE SFP28 (Broadcom 57414/57454/57504, Intel E810-DA2/DA4, Mellanox ConnectX-4 Lx/ConnectX-6 Lx, Marvell QL41232); one port can be shared with the BMC
- PCIe
- 1/10/25 GbE (incl. AMD X3522 low latency), 100 GbE (Broadcom 57508, ConnectX-6 Dx), InfiniBand HDR100/HDR (ConnectX-6)
- Fibre Channel
- Emulex LPe36002 64Gb, LPe35000/35002 32Gb (v1 with EPYC 7002, v2 with EPYC 7003), QLogic QLE2770/2772/2740/2742 32Gb, 16Gb HBAs
- Management
- 1 x RJ-45 1 GbE BMC port
Power
- PSU options
- 550 W, 750 W and 1100 W Platinum (115/230 V), 1600 W Platinum (230 V), 750 W Titanium (230 V), 1100 W -48 V DC (special bid)
- Redundancy
- 1 or 2 hot-swap PSUs; both must be identical
- Connector
- C14 inlets on AC units; Positronic connector on the -48 V DC unit; 240 V DC input in China only
- Input current
- 100-127 V: 550 W 6.2 A, 750 W 8.4 A, 1100 W 12 A; 200-240 V: 550 W 3.0 A, 750 W 4.1 A, 1100 W 6 A, 1600 W 8.7 A
- Heat output
- 123 W (421 BTU/hr) minimum to 1643 W (5606 BTU/hr) maximum configuration
- Cooling
- 6 hot-swap 60 mm single-rotor fans (5 in simple configurations), N+1; standard or performance (29,000 RPM) fan modules; one fan in each PSU
Ports
- Front
- 2 x USB 3.2 Gen 1 (5 Gbps), optional VGA on the left rack latch (disables rear VGA when used)
- Rear
- 2 x USB 3.2 Gen 1, 1 x VGA, 1 x DB-9 serial, 1 x RJ-45 BMC management, NMI button
Physical
- Form factor
- 2U rack
- Dimensions
- 445 mm W x 87 mm H x 764 mm D (17.5 x 3.4 x 30.1 in); 482 mm across the rack flanges
- Weight
- Maximum 35.4 kg (78.0 lb)
- Machine types
- 7Y00 (1-year warranty), 7Z01 (3-year warranty); 7Z01CTO2WW / 7Y00CTO2WW Workstation base models for Windows 10/11
- Environment
- ASHRAE A2 (10-35 C); some 280 W, GPU and 24 NVMe + 8 mid configurations limited to 30 C; A3/A4 only for restricted configurations (155 W max CPU, no NVMe, GPUs or 10 GbE+)
- Acoustics
- Typical 6.2 Bel / 47 dBA operating; GPU-rich up to 8.5 Bel / 69 dBA
- Rails
- Toolless slide rail (optional 2U CMA) or toolless friction rail v2; 610-864 mm between rack posts
Management
- BMC
- ASPEED AST2500 baseboard management controller with web-based ThinkSystem System Manager (TSM); remote KVM (up to 1920x1080) and virtual media are standard
- Interfaces
- IPMI 2.0 (IPMI-over-LAN disabled by default), SNMPv3, Redfish, HTML5 web UI; dedicated 1 GbE management port or NC-SI sharing (10/100 Mb) on OCP adapter port 1
- Software
- XClarity Provisioning Manager Lite (LXPM Lite), XClarity Administrator, XClarity Essentials, XClarity Energy Manager, Capacity Planner
- Security
- TPM 2.0 (Nationz TPM 2.0 in China, CTO only), NIST SP 800-147B, Secure Boot, AMD Secure Root-of-Trust, optional intrusion switch (CTO only) and lockable front bezel, power-on and administrator passwords
- Local
- Front operator panel, pull-out network information tab, light path fault LEDs for DIMMs, drives, fans and PSUs
- Announced
- Product guide first published 2019-08-07
- Withdrawn
- Withdrawn from marketing (Lenovo Press update of 2025-03-12)
Operating systems
- Windows
- Windows Server 2016, 2019, 2022; Windows 10 (x64) and Windows 11 on the SR655 Workstation base models, with a restricted adapter and drive list
- Linux
- RHEL 7.6-7.9 (EPYC 7002 only), 8.0-8.10 (8.3 and later with EPYC 7003), 9.0-9.8; SLES 12 SP4 (7002 only) and SP5, 15 SP1 (7002 only) to SP7; Ubuntu 22.04 and 24.04 LTS
- VMware
- ESXi 6.5 U3 (EPYC 7002 only), 6.7 U3, 7.0 and 7.0 U1 (EPYC 7002 only), 7.0 U2, 7.0 U3, 8.0 through 8.0 U3; factory ESXi preload available (not with NVIDIA GPUs)
Processors
- AMD EPYC 7203
- AMD EPYC 7203P
- AMD EPYC 72F3
- AMD EPYC 7303
- AMD EPYC 7303P
- AMD EPYC 7313
- AMD EPYC 7313P
- AMD EPYC 7343
- AMD EPYC 73F3
- AMD EPYC 7413
- AMD EPYC 7443
- AMD EPYC 7443P
- AMD EPYC 7453
- AMD EPYC 74F3
- AMD EPYC 7513
- AMD EPYC 7543
- AMD EPYC 7543P
- AMD EPYC 75F3
- AMD EPYC 7643
- AMD EPYC 7643P
- AMD EPYC 7663
- AMD EPYC 7663P
- AMD EPYC 7713
- AMD EPYC 7713P
- AMD EPYC 7763
- AMD EPYC 7232P
- AMD EPYC 7252
- AMD EPYC 7262
- AMD EPYC 7F32
- AMD EPYC 7272
- AMD EPYC 7282
- AMD EPYC 7302
- AMD EPYC 7302P
- AMD EPYC 7F52
- AMD EPYC 7352
- AMD EPYC 7402
- AMD EPYC 7402P
- AMD EPYC 7F72
- AMD EPYC 7452
- AMD EPYC 7502
- AMD EPYC 7502P
- AMD EPYC 7532
- AMD EPYC 7542
- AMD EPYC 7552
- AMD EPYC 7642
- AMD EPYC 7662
- AMD EPYC 7702
- AMD EPYC 7702P
- AMD EPYC 7742
- AMD EPYC 7H12