Computer Picker Pick a winner!

Dell PowerEdge R6525

Dell EMC's two-socket 1U AMD rack server: two 2nd or 3rd Gen AMD EPYC (7002/7003) processors with up to 64 cores each, 32 DDR4-3200 DIMMs, up to 3 PCIe Gen4 slots and up to 12 NVMe drives (10 front + 2 rear). Aimed at dense virtualization, VDI, HPC and databases.

Memory

Slots
32 DDR4 DIMM (16 per CPU, 8 channels x 2 DIMMs), 288-pin
RDIMM
8 GB (1R), 16/32/64 GB (2R), 3200 MT/s; max 2 TB (1 TB with one CPU)
LRDIMM
128 GB 4R (3200 MT/s) or 8R (2666 or 3200 MT/s); max 4 TB (2 TB with one CPU)
Speed
1 DPC 3200 MT/s, 2 DPC 2933 MT/s; the 128 GB 8R 2666 MT/s LRDIMM runs 2666 MT/s at both
Population
White-tab sockets first; both CPUs populated identically; odd DIMM counts allowed; no UDIMMs; mixed DIMM capacities not supported
Note
The Technical Guide intro says 2 TB max, but its tables, the Technical Specifications and the spec sheet give 4 TB with 128 GB LRDIMMs

Storage

Front bays
4 x 3.5" SAS/SATA, 8 x 2.5" SAS/SATA, or 10 x 2.5" SAS/SATA/NVMe, hot-plug
Rear bays
Optional 2 x 2.5" SAS/SATA/NVMe module (10 + 2, or 4 x 3.5" + 2); it takes the riser 1/2 area, leaving slot 3
NVMe
Up to 10 front + 2 rear U.2 PCIe Gen4
Internal RAID/HBA
PERC 10.5: H345, H745, HBA345; PERC 11: H755N, HBA355i; the front PERC module mounts at the front or rear of the backplane
Software RAID
S150 (SATA, NVMe)
External
PERC H840, HBA355E, 12 Gbps SAS HBA; 12Gb MD-series JBODs, USB tape
Boot
BOSS-S2 (rear, hot-plug) or BOSS-S1 adapter card: 2 x M.2 SATA SSD with hardware RAID
IDSDM
Optional internal dual SD module, 16/32/64 GB (second card for redundancy)
Drive types
2.5" SAS 10K 300 GB-2.4 TB, 15K 300-900 GB; SAS SSD 400 GB-3.84 TB; SATA SSD 120 GB-3.84 TB; NVMe 960 GB-15.36 TB; 3.5" SAS/SATA 7.2K 1-10 TB

Graphics

Onboard
Matrox G200, 16 MB frame buffer; rear VGA up to 1920 x 1200 at 60 Hz
Accelerators
NVIDIA T4 16 GB or A2 16 GB (75 W single-width): up to 3 low-profile (slot order 2, 1, 3) or 2 full-height (slots 2, 1)
Restriction
T4/A2 in slot 3 only with the 10 x 2.5" chassis; HPR/VHP fans and 30 C max ambient with a GPU

Expansion

Slot 1
R1a: x16 full-height 3/4-length (CPU1); R2a: x16 low-profile half-length (CPU1)
Slot 2
R2a: x16 low-profile half-length (CPU2); R4c + R4d: x16 full-height 3/4-length (CPU2)
Slot 3
R3a: x16 low-profile half-length (CPU2)
Riser configs
0 no riser; 1 R1a; 2 R2a + R3a; 4 R1a + R4c + R4d; 5 R3a; 6 R1d + R2a + R3a; 8 R1a; 9 R1a + R4c + R4d
Other
All PCIe Gen4, not hot-swappable; the optional DB-9 serial port card mounts like a slot filler in a riser

Networking

LOM
2 x 1GbE RJ45 on a LOM card
OCP 3.0
1 x OCP NIC 3.0 small-form-factor slot: 1GbE x4, 10GbE x2, 25GbE x2/x4, 50GbE x2, 100GbE x2 (Broadcom, Intel, Mellanox, QLogic, SolarFlare)
Add-in
PCIe NICs 1/10/25/50/100 GbE, Mellanox HDR/HDR100 VPI, Emulex/QLogic FC16/FC32/FC64 HBAs

Power

PSU options
800 W Platinum mixed mode (100-240 VAC / 240 VDC); 1100 W Titanium mixed mode; 1400 W Platinum mixed mode; 1100 W -48 to -60 VDC
Also listed
The Technical Guide comparison table also lists Titanium 700 W and 1800 W mixed-mode AC units
Redundancy
Two hot-plug PSUs (60 mm form factor), 1+1 redundant, one at each side of the rear
Fans
Up to 4 hot-plug dual-fan modules: STD, HPR (Silver) or HPR (Gold, VHP); N+1 redundant; fan grades cannot be mixed
Cooling
Air, or optional processor direct liquid cooling with leak sensor (liquid: 3 dual-fan modules for one CPU, 4 for two)
Battery
CR2032 3.0 V lithium coin cell

Ports

Front
VGA, 1 x USB 2.0, iDRAC Direct (micro-AB USB), power button
Rear
1 x USB 3.0, 1 x USB 2.0, VGA, iDRAC9 dedicated RJ45, 2 x 1GbE LOM, OCP 3.0 slot, system ID button, optional DB-9 serial
Internal
1 x USB 3.0

Physical

Form factor
1U rack
Dimensions
42.8 mm H x 482 mm W (434 mm without ears); bezel 35.84 mm deep (22.0 mm ear depth without bezel)
Depth
Ear to rear wall 700.53 mm (8 x 2.5") or 751.48 mm (4 x 3.5" / 10 x 2.5"); ear to PSU handle 736.27 / 787.05 mm
Weight
21.8 kg (4 x 3.5"), 19.2 kg (8 x 2.5"), 21.8 kg (10 x 2.5"), maximum
Operating temp
10-35 C (ASHRAE A2); A3 (5-40 C) and A4 (5-45 C) with configuration restrictions

Management

BMC
iDRAC9 with Lifecycle Controller, iDRAC RESTful API with Redfish, iDRAC Direct, optional Quick Sync 2 (BLE/wireless)
Software
OpenManage Enterprise, Power Manager plugin, OpenManage Mobile, iDRAC Service Module; integrations for Microsoft System Center, VMware vCenter, Red Hat Ansible, BMC TrueSight, ServiceNow; connections for IBM Tivoli, Micro Focus, Nagios
Security
TPM 1.2/2.0, TCM 2.0 optional; cryptographically signed firmware, Secure Boot, Secure Erase, Silicon Root of Trust, System Lockdown, AMD SME and SEV
Bezel
Optional LCD bezel or security bezel

Operating systems

Supported
Canonical Ubuntu Server LTS, Citrix XenServer / Hypervisor, Microsoft Windows Server with Hyper-V, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware ESXi / vSAN

Processors

  • AMD EPYC 7773X
  • AMD EPYC 7573X
  • AMD EPYC 7473X
  • AMD EPYC 7373X
  • AMD EPYC 7763
  • AMD EPYC 7H12
  • AMD EPYC 75F3
  • AMD EPYC 7742
  • AMD EPYC 7713P
  • AMD EPYC 7713
  • AMD EPYC 7702
  • AMD EPYC 7663
  • AMD EPYC 7662
  • AMD EPYC 7643
  • AMD EPYC 7642
  • AMD EPYC 7552
  • AMD EPYC 7543P
  • AMD EPYC 7543
  • AMD EPYC 7542
  • AMD EPYC 7532
  • AMD EPYC 7513
  • AMD EPYC 7502
  • AMD EPYC 74F3
  • AMD EPYC 7452
  • AMD EPYC 7443P
  • AMD EPYC 7443
  • AMD EPYC 7413
  • AMD EPYC 7402
  • AMD EPYC 7352
  • AMD EPYC 7343
  • AMD EPYC 7313P
  • AMD EPYC 7313
  • AMD EPYC 7302
  • AMD EPYC 72F3
  • AMD EPYC 7262
  • AMD EPYC 7282
  • AMD EPYC 7272
  • AMD EPYC 7232P
  • AMD EPYC 7F72
  • AMD EPYC 7F52
  • AMD EPYC 7F32
  • AMD EPYC 7252